DC/DC Converter
TEN 40 Series, 40 Watt
•
•
•
40 Watt in a 2”x2” package
•
Over temperature protection, under
voltage lockout and Remote On/Off
•
Shielded metal case with insulated
baseplate
•
Wide 2:1 input voltage range
Extended operating temperature
range: –40°C to +75°C
UL 62368-1 IEC 62368-1
The TEN 40 series is a family of high performance 40W DC/DC converter modules featuring a wide 2:1 input voltage range in a 2"x2" package. Typical applications for these products are battery operated equipment and distributed
power architectures in communication and industrial electronics.
3-years product warranty
Models
Order Code
Input Voltage
Range
TEN 40-1210
TEN 40-1211
TEN 40-1212
TEN 40-1220
TEN 40-1222
TEN 40-1223
TEN 40-1233
TEN 40-1234
TEN 40-1231
TEN 40-1232
TEN 40-2410
TEN 40-2411
TEN 40-2412
TEN 40-2420
TEN 40-2422
TEN 40-2423
TEN 40-2433
TEN 40-2434
TEN 40-2431
TEN 40-2432
TEN 40-4810
TEN 40-4811
TEN 40-4812
TEN 40-4820
TEN 40-4822
TEN 40-4823
TEN 40-4833
TEN 40-4834
TEN 40-4831
TEN 40-4832
9 - 18 VDC
(12 VDC nom.)
18 - 36 VDC
(24 VDC nom.)
36 - 75 VDC
(48 VDC nom.)
Output 1
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
+3.3 VDC
+12 VDC
+15 VDC
+3.3 VDC
+3.3 VDC
+5 VDC
+5 VDC
3.3 VDC
5 VDC
12 VDC
+3.3 VDC
+12 VDC
+15 VDC
+3.3 VDC
+3.3 VDC
+5 VDC
+5 VDC
3.3 VDC
5 VDC
12 VDC
+3.3 VDC
+12 VDC
+15 VDC
+3.3 VDC
+3.3 VDC
+5 VDC
+5 VDC
8'000 mA
8'000 mA
3'300 mA
8'000 mA
1'800 mA
1'400 mA
6'000 mA
6'000 mA
6'000 mA
6'000 mA
8'000 mA
8'000 mA
3'300 mA
8'000 mA
1'800 mA
1'400 mA
6'000 mA
6'000 mA
6'000 mA
6'000 mA
8'000 mA
8'000 mA
3'300 mA
8'000 mA
1'800 mA
1'400 mA
6'000 mA
6'000 mA
6'000 mA
6'000 mA
Output 2
Vnom
Imax
Output 3
Vnom
Imax
+5 VDC
–12 VDC
–15 VDC
+12 VDC
+15 VDC
+12 VDC
+15 VDC
8'000 mA
1'800 mA
1'400 mA
400 mA
300 mA
400 mA
300 mA
–12 VDC
–15 VDC
–12 VDC
–15 VDC
400 mA
300 mA
400 mA
300 mA
+5 VDC
–12 VDC
–15 VDC
+12 VDC
+15 VDC
+12 VDC
+15 VDC
8'000 mA
1'800 mA
1'400 mA
400 mA
300 mA
400 mA
300 mA
–12 VDC
–15 VDC
–12 VDC
–15 VDC
400 mA
300 mA
400 mA
300 mA
+5 VDC
–12 VDC
–15 VDC
+12 VDC
+15 VDC
+12 VDC
+15 VDC
8'000 mA
1'800 mA
1'400 mA
400 mA
300 mA
400 mA
300 mA
–12 VDC
–15 VDC
–12 VDC
–15 VDC
400 mA
300 mA
400 mA
300 mA
Efficiency
typ.
86 %
86 %
86 %
85 %
85 %
85 %
84 %
84 %
86 %
86 %
87 %
89 %
88 %
86 %
87 %
87 %
85 %
85 %
87 %
87 %
88 %
90 %
89 %
88 %
87 %
87 %
86 %
86 %
88 %
88 %
Options
TEN-HS3
Note
- Optional Heat Sink: www.tracopower.com/products/ten-hs3.pdf
- TEN 40-xx20: Dynamic current allocation, 8 A total output current for both outputs together
www.tracopower.com
September 20, 2023
Page 1 / 6
TEN 40 Series, 40 Watt
Input Specifications
Input Current
- At no load
- At full load
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
Input Filter
200 mA typ.
80 mA typ.
50 mA typ.
2'680 mA typ. (3.3 Vout model)
4'065 mA typ. (5 Vout model)
4'065 mA typ. (12 Vout model)
3'415 mA typ. (3.3 / 5 Vout model)
4'400 mA typ. (12 / -12 Vout model)
4'400 mA typ. (15 / -15 Vout model)
3'000 mA typ. (3.3 / 12 / -12 Vout model)
3'000 mA typ. (3.3 / 15 / -15 Vout model)
4'000 mA typ. (5 / 12 / -12 Vout model)
4'000 mA typ. (5 / 15 / -15 Vout model)
1'325 mA typ. (3.3 Vout model)
2'000 mA typ. (5 Vout model)
2'000 mA typ. (12 Vout model)
1'685 mA typ. (3.3 / 5 Vout model)
2'100 mA typ. (12 / -12 Vout model)
2'100 mA typ. (15 / -15 Vout model)
1'500 mA typ. (3.3 / 12 / -12 Vout model)
1'500 mA typ. (3.3 / 15 / -15 Vout model)
1'990 mA typ. (5 / 12 / -12 Vout model)
1'990 mA typ. (5 / 15 / -15 Vout model)
655 mA typ. (3.3 Vout model)
1'000 mA typ. (5 Vout model)
1'000 mA typ. (12 Vout model)
825 mA typ. (3.3 / 5 Vout model)
1'050 mA typ. (12 / -12 Vout model)
1'050 mA typ. (15 / -15 Vout model)
750 mA typ. (3.3 / 12 / -12 Vout model)
750 mA typ. (3.3 / 15 / -15 Vout model)
980 mA typ. (5 / 12 / -12 Vout model)
980 mA typ. (5 / 15 / -15 Vout model)
36 VDC max. (100 ms max.)
50 VDC max. (100 ms max.)
100 VDC max. (100 ms max.)
7 VDC min. / 8 VDC typ. / 8.8 VDC max.
15 VDC min. / 16 VDC typ. / 17.5 VDC max.
32.5 VDC min. / 34 VDC typ. / 35.5 VDC max.
8'000 mA (fast acting)
4'000 mA (slow blow)
2'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal LC-Type
Output Specifications
Output Voltage Adjustment
Voltage Set Accuracy
±10% (single output and dual symmetric output
models only)
(By external trim resistor)
See application note: www.tracopower.com/overview/ten40
Output power must not exceed rated power!
±1% max. (±5% for triple models, (aux))
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 6
TEN 40 Series, 40 Watt
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
- Cross Regulation
(25% / 100% asym. load)
Ripple and Noise
(20 MHz Bandwidth)
- single output
- dual output
- triple output
Capacitive Load
- single output
- dual output
- triple output
Minimum Load
- single output
- dual output
- triple output
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Time
single output models: 0.5% max.
dual output models: 0.5% max.
triple output models: 1% max.
5% max. (aux)
single output models: 0.5% max.
dual output models: 1% max. (Output 1)
1% max. (Output 2)
triple output models: 2% max. (Output 1)
5% max. (Output 2)
5% max. (Output 3)
dual output models: 5% max.
triple output models: 1% max.
5% max. (aux)
3.3 Vout: 50 mVp-p typ. (w/ 0.1 μF MLCC)
5 Vout: 50 mVp-p typ. (w/ 0.1 μF MLCC)
12 Vout: 75 mVp-p typ. (w/ 0.1 μF MLCC)
3.3 / 5 Vout: 100 / 100 mVp-p typ. (w/ 1 uF MLCC)
12 / -12 Vout: 120 / 120 mVp-p typ. (w/ 0.1 μF MLCC)
15 / -15 Vout: 150 / 150 mVp-p typ. (w/ 0.1 μF MLCC)
3.3 / 12 / -12 Vout: 50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC)
3.3 / 15 / -15 Vout: 50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC)
5 / 12 / -12 Vout: 50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC)
5 / 15 / -15 Vout: 50 / 75 / 75 mVp-p typ. (w/ 0.1 μF MLCC)
3.3 Vout: 21'000 µF max.
5 Vout: 13'600 µF max.
12 Vout: 2'360 µF max.
3.3 / 5 Vout: 11'000 / 6'800 µF max.
12 / -12 Vout: 1'200 / 1'200 µF max.
15 / -15 Vout: 750 / 750 µF max.
3.3 / 12 / -12 Vout: 13'000 / 330 / 330 µF max.
3.3 / 15 / -15 Vout: 13'000 / 110 / 110 µF max.
5 / 12 / -12 Vout: 6'800 / 330 / 330 µF max.
5 / 15 / -15 Vout: 6'800 / 110 / 110 µF max.
3.3 Vout: 0 % of Iout max.
5 Vout: 0 % of Iout max.
12 Vout: 0 % of Iout max.
3.3 / 5 Vout: 0 % of Iout max.
12 / -12 Vout: 8 % of Iout max.
15 / -15 Vout: 8 % of Iout max.
3.3 / 12 / -12 Vout: 10 % of Iout max.
3.3 / 15 / -15 Vout: 10 % of Iout max.
5 / 12 / -12 Vout: 10 % of Iout max.
5 / 15 / -15 Vout: 10 % of Iout max.
±0.02 %/K max.
25 ms typ. (Power On)
25 ms typ. (Remote On)
Continuous, Automatic recovery
150% max. of Iout max.
118 - 125% of Vout nom.
(depending on model)
3.9 VDC typ. (3.3 VDC outputs)
6.2 VDC typ. (5 VDC outputs)
15 VDC typ. (12 VDC outputs)
18 VDC typ. (15 VDC outputs)
(By Zener diode)
250 µs typ. (25% Load Step)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 6
TEN 40 Series, 40 Watt
Safety Specifications
Safety Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/ten40
PD 2
Not mains connected
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/ten40
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria B
EN 61000-4-2, ±6 kV, perf. criteria B
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria B
EN 61000-4-5, ±1 kV, perf. criteria B
220 μF / 100 V / KY
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
Over Temperature
Protection Switch Off
Cooling System
Remote Control
95% max. (non condensing)
–40°C to +75°C
+100°C max.
–55°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/ten40
115°C typ.
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
- Protection Mode
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
2.5 mA typ.
-0.5 to 0.5 mA
5'000 m max.
450 - 550 kHz (PWM) (500 kHz typ.)
(Dual models, 3.3 VDC output)
270 - 330 kHz (PWM) (300 kHz typ.)
(other models / outputs)
Functional Insulation
1'600 VDC
1'600 VDC
1'600 VDC
1'000 MΩ min.
1'000 pF max.
920'000 h (MIL-HDBK-217F, ground benign)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 4 / 6
TEN 40 Series, 40 Watt
Washing Process
Environment
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
7.6 g, 3 axis, 60 min, 20-2000 Hz
MIL-STD-810F
40 g, 3 axis, half sine, 11 ms
MIL-STD-810F
Copper, Nickel plated
Non-conductive FR4 (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper
Nickel (2 - 3 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 2"
Lead-Free Wave Soldering
265°C / 10 s max.
60 g
- Vibration
- Mechanical Shock
- Thermal Shock
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
9.2 K/W typ.
7.6 K/W typ. (with Heat Sink)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
59d98b0b-fdf8-4da8-a96c-627ba766180b
- Case to Ambient
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/ten40
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 5 / 6
TEN 40 Series, 40 Watt
Outline Dimensions
(0.9)
Pinout
2.5
22.9
(0.6)
5.08
(0.2)
3
2
Pin
(0.1)
15.24
1
Single
7
6
7.62
4
7.62 7.62
(0.3)
(0.3)
5.08
5.08
(0.2)
(0.2)
(0.3)
(2.0)
50.8
(1.8)
45.72
5
10.2
(0.4)
50.8
(2.0)
+Vin (Vcc)
+Vin (Vcc)
Triple
1
+Vin (Vcc)
–Vin (GND) –Vin (GND) –Vin (GND) –Vin (GND)
+Vin (Vcc)
Remote On/Off
4
NC
No pin
Vout 1
Vout 2
5
–Sense*
Vout 1
Common
Common
6
+Sense*
Common
NC
Vout 3
7
+Vout
Common
NC
Vout 1
8
–Vout
Vout 2
Vout 2
Common
9
Trim
Trim
Common
NC
NC: Not connected
*Sense line to be connected to the output under regard of polarity
(Ø0.04)
8
Ø1.0
9
Dual
asymmetric
2
3
Bottom view
Dual
symmetric
5.6
10.2
(0.22)
(0.4)
Dimensions in mm (inch)
Tolerance: x.xx ±0.05 (x.x ±0.02)
Tolerance: x.xxx ±0.25 (x.xx ±0.01)
Pin dimension tolerance ±0.10 (0.004)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 6 / 6